3-dimensional one point foxation with x-shaped miniplate in the cases of the zygomatic fracture.
- Author:
Sung Hoon JUNG
;
Jong Seo KIM
;
Sung Gyu PARK
- Publication Type:Original Article
- MeSH:
Edema;
Humans;
Sutures;
Zygoma;
Zygomatic Fractures*
- From:Journal of the Korean Society of Plastic and Reconstructive Surgeons
1998;25(5):837-844
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Recently the internal rigid fixation with plates and screws became popular procedure. In the cases of the zygomatic fracture, it is sufficient to fix more than 2 point in many studies. Therefore, the internal rigid fixation requires the aggressive incision to expose the zygoma, such as coronal incision. Since many patients are afraid of this aggressive operation, we have provided a simple and effective method which is a 3-dimensional one point fixation on the zygomaticofrontal suture with X-shaped(6-hole) miniplate for the treatment of zygomatic fractures. From March 1995 to september 1995, we treated 13 cases of zygomatic fractures by open reduction and X-shaped miniplate fixation on the zygomaticofrontal suture. The results were as follows: 1) plane to plane contact on each side of the fracture with one point X-shaped miniplate. 2) 91.8% correction on Water's views, and 93.3% correction on zygomatic arch view with one point fixation. 3) patients were satisfied with these procedures because of minimal incision, mild edema and low operation price (short operation & anesthetic time, one plate & 6 screws cost).