Intraocular pressure changes after hemodialysis
- Author:
Francisco Lionel-Raymond D
;
Aquino Norman M
- Publication Type:Journal Article
- MeSH:
Human;
Male;
Female;
Aged 80 and over;
Aged;
Middle Aged;
Adult;
HEMODIALYSIS;
INTRAOCULAR PRESSURE MEASUREMENT
- From:
Philippine Journal of Ophthalmology
2001;26(3):66-68
- CountryPhilippines
- Language:English
-
Abstract:
This study aims to determine if there is an intraocular pressure (IOP) change in patients undergoing hemodialysis.A total of 39 patients from 2 hemodialysis centers in Metro Manila were enrolled in the study.IOP measurements of both eyes were done using a Perkins applanation tonometer.Measurements were done before 2 hours into, and immediately after hemodialysis.Statistical analysis using the Wilkoxon Matched Pairs Signed 2-tailed Test showed a significant decrease in intraocular pressure (P-0.0001) with a mean decrease of 2.41 mm Hg (SD 1.09), OD and 2.36 mm Hg (SD 1.22), OS.This study shows that there is a significant change in IOP after undergoing hemodialysis