Retrofitting and purposed-built buildings: indoor air quality and sick building syndrome among private higher learning institution students in Kuala Lumpur and Selangor
- Author:
Nor Faeiza M, Juliana J, Chua PH
- Publication Type:Journal Article
- Keywords:
Indoor Air Quality, Sick Building Syndrome, Retrofitting Built Building, Proposed Built Building.
- From:Malaysian Journal of Public Health Medicine
2016;16(Supplement 2):106-112
- CountryMalaysia
- Language:English
-
Abstract:
This study was done to determine the relationship between indoor air quality and Sick Building Syndrome (SBS)
among students in Retrofitting Building (Building A) located in Kuala Lumpur and Purposed-built Building (Building B)
located in Selangor. A cross sectional study was conducted among student from selected buildings with the total
number of 130 respondents. Modified questionnaire based on Indoor Air Quality and Work Symptoms Survey, NIOSH,
Indoor Environmental Quality Survey, 1991 was used to record the number of students experienced SBS. Measurement
of indoor air quality was performed using instruments recommended by the IAQ Code of Practice, Department of
Occupational Safety and Health, Malaysia. There was a significantly higher number of occupants experienced SBS in
Building A (60 of 65 respondents) compared to Building B (50 of 65 respondents) (Χ
2
= 4.127, p = 0.042). It was also
found that there is a significant difference between the numbers of respondents having SBS between Building A and
Building B (p < 0.045). Building A had higher CO2, bacteria, fungi, and UFP significantly as compared to Building B.
However, only CO was significantly higher in Building B compared to Building A. It is suggested thatregular
maintenance of both buildings is compulsory as ventilation played an important role in maintaining good indoor air
quality in a building.