Ultrasound combined with tri-operators and the blood-oxygen functional image technology in diagnosis of breast cancer in young women
10.3760/cma.j.issn.1674-6090.2010.05.012
- VernacularTitle:三算子及血氧功能成像技术联合超声在年轻女性乳腺癌诊断中的应用研究
- Author:
Jianhua SHI
;
Linlin ZHEN
;
Xuedong HAN
;
Meiping SHEN
- Publication Type:Journal Article
- Keywords:
Tri-operators and the blood-oxygen functional image technology;
Breast cancer;
Ultrasonography;
Sensitivity;
Accuracy
- From:
Journal of Endocrine Surgery
2010;04(5):324-326,330
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate ultrasound combined with thri-operators and the blood-oxygen functional image (TOBOFI) technology in diagnosis of breast cancer in young women. Methods 221 breast tumor patients under 45 years old were selected to analyze their TOBOFI and ultrasonographic characteristics respectively. Based on pathological result, the two diagnostic methods were compared to determine the accurate rate. Results Of all the 221 patients, 82 (37.1%) were malignant and 139 benign. The sensitivity of TOBOFI and ultrasonography was 90.24% and 83.57% respectively, while the accurate rate of the two was 89.14% and 84 62% respectively. Accurate rate was improved to 93.90 % (77/82) if the two were combined. Conclusion TOBOFI has unique clinical value in diagnosing breast cancer in young women, especially in combination with ultrasound.