The Relationship of the Anthropometric Variables to the Infusion Rate of Rocuronium in the Elderly.
10.3349/ymj.2005.46.5.643
- Author:
Bon Nyeo KOO
1
;
Sun Jun BAI
;
Yang Sik SHIN
;
Woo Chang LEE
Author Information
1. Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea. koobn@yumc.yonsei.ac.kr
- Publication Type:Original Article
- Keywords:
Anthropometric variables;
elderly patients;
infusion rate;
neuromuscular monitoring;
rocuronium
- MeSH:
Skinfold Thickness;
Neuromuscular Nondepolarizing Agents/*administration & dosage;
Middle Aged;
Male;
Infusions, Intravenous;
Humans;
Female;
Body Weight;
Body Surface Area;
Body Mass Index;
Body Height;
*Anthropometry;
Androstanols/*administration & dosage;
Aged;
Adult
- From:Yonsei Medical Journal
2005;46(5):643-647
- CountryRepublic of Korea
- Language:English
-
Abstract:
We have determined the infusion rates of rocuronium in the elderly and young adult patients during sevoflurane and nitrous oxide anesthesia. The correlation of some anthropometric predictors with infusion rate of rocuronium was also investigated for both elderly and young adult. Participating patients were assigned to one of two groups: 1) young adult patients aged 20 to 50 years (n = 30) ; 2) elderly patients aged over 65 years (n = 30). The anthropometric variables such as height, weight, ratio of weight to body surface area, subscapularis and suprailiac skin folds, body surface area, body mass index and % ideal body weight were evaluated as predictors for infusion rate. The infusion rate in elderly patients was significantly less compared with that in young adult patients (p < 0.05). In elderly patients, no anthropometric predictor was related to the infusion rate of rocuronium. This suggests that the infusion rate of rocuronium for an elderly patient needs to be individualized by monitoring neuromuscular transmission to avoid excessive dose.