Value of 99Tcm-Tilmanocept and 99Tcm-sulfur colloid SPECT/CT for the detection of sentinel lymph node in breast cancer patients
10.3760/cma.j.issn.2095-2848.2017.07.002
- VernacularTitle:99Tcm-TMC与99Tcm-SC SPECT/CT探测乳腺癌前哨淋巴结的价值
- Author:
Yan LIU
;
Zongwei HUO
;
Xiaohui WANG
;
Qi KONG
;
Jiazhong REN
;
Guoren YANG
- Keywords:
Breast neoplasms;
Sentinel lymph node;
Tomography;
emission-computed;
single-photon;
Tomography;
X-ray computed;
Mannosides;
Technetium Tc 99m sulfur colloid
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2017;37(7):388-391
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the clinical value of 99Tcm-Tilmanocept(TMC) SPECT/CT for the detection of SLN by comparing with 99Tcm-sulfur colloid(SC) SPECT/CT. Methods From March 2016 to September 2016, a total of 160 patients (age range: 30-70 years), selected from Breast Surgery Department of Shandong Cancer Hospital, underwent SPECT/CT and planar imaging with either 99Tcm-TMC (TMC group, n=76) or 99Tcm-SC (SC group, n=84). The results of SLN SPECT/CT and planar imaging were compared. The positive rate of SLN in SPECT/CT was compared with operative results. One-way analysis of variance, χ2 test, and two-sample t test were used for data analysis. Results The radiochemical purity of 99Tcm-TMC (≥92%) had no significant difference in 4 h(F=0.720, P>0.05). In TMC group, the average number of SLN detected by SPECT/CT imaging was higher than that by planar imaging (1.34±0.64 vs 0.96±034; t=4556, P<005). In SC group, the average number of SLN detected by SPECT/CT imaging was also higher than that by planar imaging (2.57±0.99 vs 1.56±0.87; t=7.010, P<0.05). The positive rates of SLN in TMC and SC groups were 94.7%(72/76)and 96.4%(81/84), showing no significant difference (χ2=0273, P>0.05). The average number of SLN detected by 99Tcm-TMC imaging was significantly lower than that detected by 99Tcm-SC (t=9.115, P<0.05). The intraoperative detection rates of SLN were 100% (76/76 and 84/84) in both groups. The average number of SLN detected during operation in TMC group was significantly lower than that in SC group (1.89±0.86 vs 3.05±1.29; t=6.642, P<0.01). In TMC group, the average number of SLN detected during operation was significantly higher than that detected by SPECT/CT(1.89±086 vs 1.34±0.64; t=4.492, P<0.05). In SC group, the average number of SLN detected during operation was significantly higher than that detected by SPECT/CT(3.05±1.29 vs 2.57±0.99; t=2.740, P<005). Conclusions SPECT/CT is superior to planar imaging for the detection and localization of SLN. 99Tcm-TMC is suitable for SLN imaging and intraoperative detection.