Full range of vision and pseudoaccommodation in early stage after multifocal intraocular lens implantation
10.13389/j.cnki.rao.2017.0145
- VernacularTitle:多焦点人工晶状体植入术后早期全程视力和拟调节力的临床观察
- Author:
Jie WU
;
Lei ZHU
- Keywords:
phacoemulsification;
multifocal intraocular lens;
monofocal intraocular lens;
pseudoaccommodation
- From:
Recent Advances in Ophthalmology
2017;37(6):572-575
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the clinical effectiveness and pseudoaccommodation in the early stage after AcrySof ReSTOR multifocal intraocular lens (IOL) and monofocal IOL implantation.Methods A total of 138 patients (158 eyes) with age-related cataract underwent phacoemulsification and IOL implantation were chosen,73eyes of 60 patients with a multifocal IOL implantation as observation group and 85 eyes of 78 patients with monofocal IOL implantation as control group.The uncorrected visual acuity,best corrected visual acuity was evaluated at 1 week,1 month,and 3 months after operation,pseudoaccommodation and quality of life was evaluated at 3 months after operation.Results The patients of both observation group and control group were able to obtain a satisfactory distance vision at 1 week,1 month,and 3 months.The uncorrected intermediate visual acuity of observation group were 0.49 ± 0.19,0.72 ± 0.21,0.77 ±0.23,which of control group were 0.24 ± 0.21,0.27 ± 0.22,0.28 ± 0.24,there were statistical differences between two groups (all P < 0.05).The uncorrected near visual acuity of observation group were 0.47 ± 0.20,0.70 ± 0.22,0.80 ± 0.24,which of control group were 0.21 ±0.23,0.23 ±0.19,0.26 ±0.18,there were statistical differences between two groups (all P < 0.05).There was no significant difference in the uncorrected near visual acuity,best corrected distance,intermediate and near visual acuity between observation group and control group (all P > 0.05).At 3 months,the distance and near pseudoaccommodation of observation group were (2.56 ± 0.82) D,(3.19 ±1.13)D,which of control group were (0.87 ±0.57)D,(1.03 ±0.59) D,there were statistical differences between two groups (all P < 0.05).At 3 months,VF-14 scale score and wearing glasses as near score of observation group were 92.21 ±4.22,4.23 ±0.85,which of control group were 71.23 ± 3.96,2.01 ± 0.71,there were statistical differences between two groups (all P < 0.05).Conclusion AcrySof ReSTOR multifocal intraocular lens implantation can provide a higher level of visual acuity,pseudoaccommodation and satisfaction compared with monofocal intraocular lens.