Clinical application of self-made distal femur alignment cutting template in total knee arthroplasty
10.3760/cma.j.issn.0253-2352.2017.11.003
- VernacularTitle:自制股骨远端髓外定位截骨模板在全膝关节置换术中的应用
- Author:
Hong LI
;
Zhe SUN
;
Zhifu HU
;
Chang ZHAO
;
Yue LI
;
Chaojun SUN
- Keywords:
Arthroplasty,replacement,knee;
Fiducial markers;
Femur
- From:
Chinese Journal of Orthopaedics
2017;37(11):660-669
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the accuracy and feasibility of primary total knee arthroplasty (TKA) assisted by the self-made extramedullary osteotomy template on distal femur alignment.Methods We retrospectively analyzed the clinical data of 40 patients with osteoarthritis or rheumatoid undergoing primary TKA from September 2015 to March 2016.All patients were divided into two groups,extramedullary group and intramedullary group.Extramedullary group had 20 patients (4 males and 16 females) aged 65.1±6.9 years (range 51-75).Intramedullary group had 20 patients (3 males and 17 females) aged 65.7±7.9 years (range 48-75).The blood loss volume,drainage in operation,postoperative range of motion (ROM) at 1 week and 2 weeks,deviation between the ideal value and preoperative hip-knee-ankle (HKA) angle,coronal and sagittal angle of the femoral prosthesis were compared within the two groups.Results The age,gender,body mass index,deviation between the ideal value and preoperative HKA angle,Hospital for Special Surgery (HSS) scoring system,ROM of knee were not significantly different between the two groups.The operation time was 97.4± 14.0 min in extramedullary group and 111.7±9.9 min in intramedullary group (P < 0.05).The blood loss was 71.8± 14.0 ml in extramedullary group and 111.7± 10.0 ml in intramedullary group (P < 0.05),while the drainage volume was 167.0±74.5 ml in extramedullary group and 243.2±91.6 ml in intramedullary group (P< 0.05).The postoperative mean deviation of the HKA angle in extramedullary group (2.37°±0.73°) was smaller than that in intramedullary group (3.26°±1.42°).Furthermore,the coronal alignment of the femoral prosthesis in extramedullary group (89.70°±1.91°) was larger than that in intramedullary group (87.69°±2.39°).The sagittal alignment of the femoral prosthesis in extramedullary group (90.03°±2.62°) was also significantly larger than that in intramedullary group (88.07°±2.43°,P < 0.05).The postoperative ROM of knee at 1 and 2 week in the extramedullary group were 101.75°±7.48° and 114.00°±7.88° respectively,while those in the intramedullary group were 101.25°±8.41° and 114.25°±8.78°.There was no statistically different between the two groups.There was no intraoperative and postoperative early complications reported in the two groups.Conclusion Although the primary TKA assisted by the selfmade extramedullary osteotomy template on distal femur alignment can shorten operation time,decrease the blood loss and increase the accuracy of coronal and sagittal alignment,the HSS score and ROM of knee are similar as intramedullary method.