The effects of fluor-hydroxyapatite coating on the osseointegration and peri-implantitis of orthodontic micro-implants
10.3969/j.issn.1001-3733.2015.05.006
- VernacularTitle:含氟羟基磷灰石涂层对正畸微种植体骨结合及周围炎的影响
- Author:
Yuansheng DING
;
Yue ZHAO
;
Rui GUO
;
Juan ZENG
;
Gang ZHAO
- Keywords:
Fluor-hydroxyapatite (FHA);
Orthodontic micro-implant;
Gingival crevicular fluid (GCF)
- From:
Journal of Practical Stomatology
2016;32(5):624-626
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To study the effects of fluor-hydroxyapatite (FHA) coating titanium alloy on the osseointegration and peri-implantitis of orthodontic micro-implant.Methods:Titanium of FHA alloy (FHA group) and titanium alloy(control group) orthodontic micro-implants were respectively planted into buccal alveolar bone in mandibular premolar area of rabbits.Scanning electron microscope was used to observe the osseointegration around the micro-implants.ELISA was employed to detect TNF-α in the gingival crevicular fluid around the implants.Results:The FHA-coating titanium alloy orthodontic micro-implants led to higher bone density,smaller marrow cavity,and lower TNF-α level and shorter lasting period of TNF-α over-expression than the controls (P < 0.05).Conclusion:The FHA-coating titanium alloy orthodontic micro-implant has better histocompatibility and may inhibit peri-implantitis.