Effect on threshold of triggered angiographic acquisition of renal artery CTA by different iodine flow rate
10.13929/j.1003-3289.201611154
- VernacularTitle:不同碘流率对肾动脉CTA图像最佳触发阈值的影响
- Author:
Xiaojing KAN
;
Ying GUO
;
Shufang WEI
;
Feifei GAO
;
Pengming WANG
;
Yinghui GE
- Keywords:
Renal artery;
Tomography,X-ray computed;
Angiography;
Monitored-triggered technique
- From:
Chinese Journal of Medical Imaging Technology
2017;33(7):1076-1079
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the effect on threshold of triggered angiographic acquisition by different iodine flow rate on renal artery CTA using Smart Prep tracking technique.Methods A total of 420 patients were randomly divided into A-D group with iodine flow rate of 0.90 gI/s,1.11 gI/s,1.20 gI/s,1.48 gI/s on average respectively.And each group were divided 7 subgroups with threshold 140-<150 HU,150-< 160 HU,160-< 170 HU,170 <180 HU,180 <190 HU,190-<200 HU,200-210 HU respectively.The quality of the images were graded from 1 5 by 2 radiologists.The best image quality subgroups were achieved,and the scores were compared among the best image quality subgroups.Results Image quality of renal CTA in each group were best performed with a threshold of 170-< 190 HU,160-< 190 HU,170-< 180 HU,160-< 180 HU respectively.When the threshold were 170-<180 HU,image quality were good with all iodine flow rate groups.There was no significant difference among the scores of the best image quality subgroups (all P>0.05).Conclusion Different iodine flow rate with appropriate threshold can acquire better image quality of renal CTA.