Application Value of Ultrasound Elastography Techniques in the Treatment of Uterine Fibroids Radiofrequency Ablation
10.13241/j.cnki.pmb.2017.25.041
- VernacularTitle:弹性成像技术在子宫肌瘤射频治疗中的应用价值
- Author:
Jingyu DUAN
;
Xiaoqiu DONG
;
Liwei ZHANG
;
Dejiao KONG
;
Xiaohui SHAO
- Keywords:
Uterine fibroids;
Radiofrequency ablation;
Real-time ultrasound elastography
- From:
Progress in Modern Biomedicine
2017;17(25):4967-4970,4966
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the application value of real-time ultrasound elastography in the treatment of fibroids radiofrequency ablation (RFA).Methods:Transvaginal ultrasonography,Real-time ultrasound elastography (RTE) and contrast-enhanced ultrasonography (CEUS) were performed on 34 patients with a total of 38 uterine fibroids who had the treatment of RFA before,1 hour and 3 months after the treatment of RFA.Detected the diameters of the lesions with the three methods of CEUS,RTE and 2D.Analysed the elastic image features and divided into groups,Measured the elastic strain ratio and compared the E/E0 in and between the group.The difference of lesion diameter between 2D,RTE and CEUS was compared.When the image of lesions showed blue and green was taken as the cirterion of incomplete ablation after RFA,conpared with CEUS,analysed the consistency of RTE and CEUS in evaluating the degree of ablation.Results:The lesions were divided into 3 groups according to the preoperative elastic image,with 8 (21.1%) in the blue group,20 (52.6%) in blue-based and 10 (26.3%) in green-based group.The difference was obvious in E/E0 between the 3 groups before RFA.There was no significant difference in E/E0 between 1 hour and 3 months after RFA (P > 0.05).In each group the E/E0 of lesions were significantly increased at 1 hour and 3 months after the treatment of FRA,and the hardness of 3 months after RFA was harder than that of 1 hour after RFA(P<0.05).The diameter measured by RTE was larger than that by 2D and CEUS before RFA(P>0.05).The diameter measured by 2D was larger than that by RTE and CEUS at 1 hour after RFA (P<0.05).No statistically significant difference was found in the lesion diameters among the three methods of2D,RTE and CEUS at 3 months after the treatment ofRFA (P>0.05).CEUS and RTE had the basic consistent in the evaluation of lesions ablation degree at 1 hour (kappa=0.46) and 3 months (kappa=0.54) after the treatment of RFA.Conclusions:After RFA,the myoma gradually hardens,and RTE can reflect the change of the hardness,RTE can clearly show the boundary of uterine ftbroids especially after the treatment of RFA,can be used in the prediction of lesions ablation degree,so there was a certain application value of RTE used in RFA.