Correlation research of renal perfusion and diffusion function using MRI in renal allograft early after renal transplantation
10.3760/cma.j.issn.1005?1201.2017.09.012
- VernacularTitle:MRI评价肾移植术后早期移植肾灌注及扩散功能相关性的研究
- Author:
Lihua CHEN
;
Tao REN
;
Chenglong WEN
;
Fan MAO
;
Shuangshuang XIE
;
Lixiang HUANG
;
Zhen WANG
;
Yingxin FU
;
Panli ZUO
;
Shuang XIA
;
Wen SHEN
- Keywords:
Kidney transplantation;
Renal insufficiency;
Magnetic resonance imaging
- From:
Chinese Journal of Radiology
2017;51(9):689-694
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the correlationships between microperfusion diffusion indexes derived from intravoxel incoherent motion(IVIM)and perfusion values measured by arterial spin labeling (ASL)in renal allograft. Methods A total of 76 renal allograft recipients and 26 age-matched volunteers (group 0)were included in this prospective study. All subjects were underwent conventional MRI, IVIM and ASL MRI which were performed in the oblique-sagittal plane. Seventy-six recipients were divided into two groups based on the estimated glomerular filtration rate(eGFR):recipients with good allograft function(group 1, eGFR≥ 60 ml · min-1 · 1.73m-2,n=44)and recipients with impaired allograft function(group 2, eGFR<60 ml · min-1 · 1.73m-2,n=32). Three IVIM indexes values, including true diffusion coefficient(ADCslow), pseudo-diffusion coef fi cient(ADCfast), perfusion fraction(PF), and one ASL index value of renal cortex(renal blood flow, RBF)were measured. One-way analysis of variance and the least significant difference were used to compare the different of each cortical index values among three groups. Correlations between the ADCslow, ADCfast, PF, RBF and eGFR as well as the correlation among the indexes were evaluated using Pearson correlation coefficients. Results For cortical ADCslow, ADCfast, PF and RBF values, allografts with good function and impaired function showed significantly differences compared healthy controls(all P<0.01). In allografts with good function, cortical ADCslow,ADCfast,PF showed no significantly differences compared with controls(all P>0.05), but RBF value was significantly lower(P<0.05). The ADCslow, ADCfast, PF and RBF values of renal cortex were significantly lower in allografts with impaired function compared to allografts with good function(all P<0.01). In renal allografts, there were significant positive correlations between cortical ADCslow, ADCfast, PF, RBF value and eGFR(r values were 0.604, 0.552, 0.579 and 0.673, all P<0.01). Cortical ADCfast and PF value exhibited a significant correlation with RBF for recipients(r values were 0.501 and 0.423, all P<0.01). Conclusion Cortical ADCfast and PF values derived from IVIM and RBF measured by ASL show a significant positive correlation in renal allografts.