Diagnostic value of DCE-MRI and BI-RADS-MR in differentiation of breast lesions
10.3969/j.issn.1006-5725.2017.16.045
- VernacularTitle:DCE-MRI与BI-RADS-MR对乳腺肿块的诊断价值
- Author:
Yuanyuan QI
;
Yang GUO
;
Xianglin ZHANG
- Keywords:
breast neoplasms;
breast diseases;
magnetic resonance imaging;
dynamic contrast-enhanced
- From:
The Journal of Practical Medicine
2017;33(16):2780-2783
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the diagnostic value of DCE-MRI and breast MR reporting and data system(BI-RADS-MR)in differentiation of breast lesions. Methods Seventy-five patients with 75 pathological-confirmed breast lesions underwent DCE-MRI before treatment and DCE-MRI quantitative analysis. Two senior doc-tors assessed the imaging features blindly by BI-RADS-MR. The pathology results were set as a gold standard. The receiver operating characteristic curve(ROC)interpretation of two physician′s curve analysis was used to evaluate the sensitivity,specificity of BI-RADS classification. Results According to the BI-RADS MR score,38 breast cancer patients were rated as 1 case in grade Ⅰ,0 case in grade Ⅱ,4 cases in gradeⅢ,13 cases in gradeⅣ,20 cases in grade V;37 breast benign tumors were rated as 17 cases in grade Ⅰ,5 cases in grade Ⅱ,12 cases in gradeⅢ,3 cases in gradeⅣandⅤ0 cases. The statistical difference of Tpeak,S max,K1 between benign and malig-nant breast tumors were significant(P<0.05). On ROC,the area under the curve was 0.940,95%confidence in-terval was from 0.887 to 0.994. The sensitivity of BI-RADS in the diagnosis of breast cancer was 94.59%and speci-ficity was 92.11%. Conclusion DCE-MRI combined with BI-RADS-MR classification in diagnosis of benign and malignant breast tumors has an important value and can improve diagnosis and differential diagnosis level.