The diagnostic value and clinical relevance of estradiol and estradiol/testosterone for female postmenopausal osteoporosis
10.3760/cma.j.issn.1009-9158.2017.08.007
- VernacularTitle:血清E2和E2/T比值对绝经后女性骨质疏松诊断的临床价值
- Author:
Haijuan LIU
;
Yan LI
;
Fangyuan ZHOU
- Keywords:
Osteoporosis,postmenopausal;
Bone density;
Estradiol;
Testosterone
- From:
Chinese Journal of Laboratory Medicine
2017;40(8):583-588
- CountryChina
- Language:Chinese
-
Abstract:
Objective To analyze the correlation of serum estradiol (E2),testosterone (T),estradiol/testosterone (E2 /T) ratio and BMD(Bone mineral density), bone turnover markers in postmenopausal women, and then to provide a theoretical basis for the pathogenesis of postmenopausal osteoporosis.It might point to a new diagnostic indicator for postmenopausal osteoporosis (PMOP).MethodsFrom October 2014 to September 2016, 283 cases of postmenopausal women were recruited from the Renmin Hospital of Wuhan University.Bone mineral density was measured by dual energy X-ray absorption apparatus, and the recruiters were classified into three group: normal controls (95 cases), osteopenia (94 cases) and osteoporosis group (94 cases).Serum calium (Ca),alkaline phosphatase (ALP),and propetide of type-Ⅰ procollagen (PINP) and β C-terminal cross-linked telopeptide of type I collagen (β-CTX) were detected by Roche cobas 6000 analyzer.Serum E2 and T were measured by Siemens Advia Centaur XP analyzer.All statistical analyses were carried out using SPSS 15.0 software.Results Compared with the normal controls, Serum E2[(22.65±5.35)pg/ml vs (18.64±6.18 )pg/ml,(17.04±6.73) pg/ml,P<0.01]and E2/T ratio (9.03±3.21 vs 7.44±1.78,6.67±1.50,P=0.01) were significantly decreased in the group of osteopenia and osteoporosis.But the bone turnover marker PINP was significantly increased[(38.92±19.23) ng/ml vs (43.94±15.52) ng/ml,(46.28±19.21) ng/ml,P=0.04].Correlation analysis results showed that serum E2 and E2/T ratio was negatively correlated with PINP (r=-0.273,P<0.05;r=-0.284,P<0.05),but positively associated with total hip BMD(r2=0.053,P=0.001;r2=-0.136,P<0.001).Multiple linear regression analysis showed serum E2 and E2/T ratio could explain 17.6% and 28.9% of the total hip BMD variance after adjustment for age, BMI and years after menopause.The area under curve (AUC) of combined E2 and E2/T as a indicator for the diagnosis of PMOP was 0.824 (95% CI:0.765-0.884,P<0.01), which was significantly better than that of E2 or E2/T (P<0.01) only.Conclusions Serum E2 and E2/T ratio was negatively correlated with PINP, but positively associated with total hip BMD.The decrease of serum E2 and E2/T ratio showed a strong association with PMOP.The combined detection of E2 and E2/T is expected to be a valuable indicator for the prediction of PMOP and to monitor the process of osteoporosis.