The aortic valve reconstruction with autologous pericardium by individual sizing technique
10.3760/cma.j.issn.1001-4497.2017.07.006
- VernacularTitle:个体模具化测量自体心包主动脉瓣成形技术
- Author:
Haibo ZHANG
;
Xu MENG
;
Jie HAN
;
Yan LI
;
Chunlei XU
;
Jiangang WANG
;
Wen ZENG
;
Yixin JIA
- Keywords:
Autologous pericardium;
Aortic valve repair
- From:
Chinese Journal of Thoracic and Cardiovascular Surgery
2017;33(7):404-407
- CountryChina
- Language:Chinese
-
Abstract:
Objective To conclude the preliminary results of aortic valve repair with autopericardium.Methods After routine median sternotomy the pericardium was isolated and immersed into the 0.6% glutaraldehyde immersion for 10 minutes, then rinsed off before use.Conventional extracorporeal circulation was established and diseased aortic valves were removed.The curves lengths between three commissures measured with the specific sizers.The corresponding size of the pericardial patchs was used to cut the new aortic leaflets.The continuous Johnson Prolene 4-0 sutures were used to fixed the new aortic valve leaflets to the anulus.Another new 4-0 prolene suture were used to fix the new three commissures outside the aortic wall with mat.The new mat stripes were used to fix the sinus in condition with the aortic sinus dilation or bileaflets malformation.Results Since 2015 October total 27 patients received aortic valve repair with autologous pericardium.The age was in the range of 27 to 60 years old including 18 female and 9 male.There were 7 cases diagnosed as aortic valve stenosis and 20 cases aortic insufficiency.And there were 3 cases bileaflets aortic valve deformity.The mean bypass time is(104±25)mins.Postoperative esophageal ultrasound showed good coaptation of the aortic valve without significant regurgitation.The mean transvalve gradient was(8.5±3.2)mmHg(1 mmHg=0.133 kPa).In the early stage one case diagnosed with aortic valve stenosis and regurgitation received monocusp repaired with autologous pericardial leave.But there was still moderate aortic regurgitation and had to receive the aortic valve replacement.All patients recovered well and were treated with Aspirin for 6 months.The followed up lasted for 3 to 13 months.Mean aortic occlusion time was(104±25) minutes.The patients were followed up for 3-13 months, the cardiac function and aortic valve function were stable, and no gradient increased.Conclusion It is relatively simple to perform the aortic valve repair with individual autologous pericardial sizer technique and the primary clinic results are satisfactory.It is worthy of further study and long-term follow-up.