Guidelines for hybrid PET/MR in brain imaging (2017 Edition)
10.13929/j.1003-3289.201702019
- VernacularTitle:一体化PET/MR颅脑成像检查规范(2017版)
- Author:
Jie LU
;
Miao ZHANG
;
Jiliang FANG
;
Lin AI
;
Xiaoli LAN
;
Biao LI
;
Changjing ZUO
;
Yaming LI
- Keywords:
Brain;
Positron-emission tomography;
Magnetic resonance imaging
- From:
Chinese Journal of Medical Imaging Technology
2017;33(5):791-794
- CountryChina
- Language:Chinese
-
Abstract:
The hybrid PET/MR has been gradually applied in clinical practice.However,the hybrid PET/MR is a com plex advanced technique,and it brings to the new challenges,especially regarding the workflow and scan protocols.The guidelines for hybrid PET/MR in brain imaging include information related to the indications and contraindications,preparation before examination,procedures of examination (PET imaging,conventional MRI brain imaging and special MRI imaging for brain disease),application of radiopharmaceutical and MRI contrast-enhanced agent.The purpose of the guidelines is to offer a framework that would be practical and helpful for clinical PET/MR brain imaging.In PET tracers,the guidelines only limit to the 18 F-FDG.