Determination of Paraquat in Human Plasma by Solid Phase Extraction-HPLC
10.6039/j.issn.1001-0408.2015.29.16
- VernacularTitle:固相萃取-HPLC法测定人血浆中百草枯的浓度
- Author:
Xiaojing WANG
;
Xianglin KONG
;
Xuwang CHEN
;
Ruichen GUO
- Publication Type:Journal Article
- Keywords:
Paraquat;
Solid phase extraction-HPLC;
Human plasma
- From:
China Pharmacy
2015;(29):4080-4081,4082
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To develop a method for the determination of paraquat in human plasma,and to provide experimen-tal evidence for the therapy and prognosis of paraquat-poisoned patients. METHODS:The human plasma samples were processed using Waters Oasis solid phase extraction column. HPLC determination was performed on DiamonsilTM C18 chromatographic column with mobile phase consisted of 0.1 mol/L phosphate buffer(containing 80 mmol/L sodium heptanesulfonate,pH adjusted to 3.0 by triethylamine)-acetonitrile (82∶18,V/V) at the flow rate of 0.9 ml/min. The detection wavelength was set at 258 nm. RESULTS:The linear range of paraquat were 20-5 000 ng/ ml;RSDs of inter-day and intra-day both were lower than 9%;average extraction recoveries were 90.72%-96.34%,and average method recoveries were 100.32%-103.10%. CONCLUSIONS:The solid phase ex-traction HPLC can determine the content of paraquat in human plasma rapidly and accurately.