Different type of anesthesia affect radiation dose when do interventional therapy for patent ductus arteriosus
10.3969/j.issn.1002-1671.2016.08.025
- VernacularTitle:不同麻醉方式在小儿动脉导管未闭介入治疗中辐射剂量分析
- Author:
Shunqiang CHEN
;
Ying GUO
;
Dapeng SHI
;
Enfeng WANG
;
Zhong ZHANG
- Publication Type:Journal Article
- Keywords:
patent ductus arteriosus;
interventional therapy;
child
- From:
Journal of Practical Radiology
2016;32(8):1262-1264,1292
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate radiation dose diffent type of anesthesia affected radiation dose when we do interventional therapy for child patent ductus arteriosus (PDA).Methods From 201 1 to 2014,we collected 50 children(3-6 years old)with PDA which received interventional therapy were included in the study.They were divided into two groups:group A (25 cases,male/fe-male=7/18,mean weight=1 5.32 kg±2.41 5 kg)underwent interventional therapy of PDA under general anesthesia,and group B (25 cases,male/female=13/12,mean weight=1 6.40 kg±2.056 kg)using local anesthesia.The surgery were operated by the same doctor,we used DSA children cardiovascular film AE mode (ped CARD)to monitor the surgery,image frames 1 5-30 f/s,used the non-ionic contrast agent (Iodixanol 320 mg I/mL)and recorded the child cumulative incidence of skin surface dose (AK),dose area product(DAP),and time of fluoroscopy,and do statistical analysis.Results All 50 cases were performed the surgery successfully. There were no significant difference of age,weight and gender between groups (age:t=1.924,P =0.06;weight:t =1.703,P =0.095;gender:χ2 =3.00,P =0.083).The cumulative incidence of skin surface dose (AK),dose area product (DAP)and time of fluoroscopy were (0.061±0.025)Gy,(5.08±2.19)Gy·cm2 and (3.15±1.16)min in A group,and (0.094±0.046)Gy,(8.41±3.587)Gy·cm2 , (6.86±3.27)min in B group.The sequence and image number of two groups were same.There were significantly differences of cumulative incidence of skin surface dose (AK),dose area product (DAP)and time of fluoroscopy between two groups (AK:t =3.152,P =0.003;DAP:t =3.957,P =0.000;time of fluoroscopy:t =5.346,P =0.000).The radiation doses of A group significantly lower than B group,compared with B group,the radiation dose were 40 percent [(1-5.08/8.41)%]lower in A group,the 1.1 7 times discrepancy of time of fluoroscopy between two group [(3.1 5-6.86)/3.1 5].Conclusion Radiation dose is associated with type of anesthesia. Compared with local anesthesia,radiation dose reduced 40% using general anesthesia during interventional therapy for PDA.