Reading and displaying DICOM RT structure based on Matlab
10.3969/J.ISSN.1672-8270.2016.06.002
- VernacularTitle:基于自设计图像处理技术实现放射治疗文件的读取和显示
- Author:
Wang ZHOU
- Publication Type:Journal Article
- Keywords:
Matrix laboratory;
Digital imaging and communications in medicine;
Computed tomography;
RT structure
- From:
China Medical Equipment
2016;13(6):5-7,8
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To design a software to read and display CT and RT structure and draw a new contour without treatment planning system (TPS).Methods: In order to display the contour information drawn by doctors, the first step was to match CT images and RT structure then the same screen rendering of CT and RT structures could be applied. In order to add contour in RT structure obtaining the coordinates interactively, connecting coordinate points were the essential steps. Then a unique identity was given in the area of that contour to ensure its unique results. Results: The software successfully read and displayed CT and RT structures and drew a new contour without TPS.Conclusion: In this study, the software establishes a basis to improve the precision of the radiotherapy dose.