Clinical effects of Zero-P vs.traditional titanium plate for single level cervical spondylosis
10.7652/jdyxb201602005
- VernacularTitle:颈前路“零切迹”椎间融合器与传统钛板融合器内固定治疗单节段颈椎病的疗效比较
- Author:
Ning WANG
;
Baixiang HE
;
Gang BAO
;
Minxue LIAN
;
Chuankun LI
;
Haiping LIAN
- Publication Type:Journal Article
- Keywords:
cervical spondylosis;
anterior cervical discectomy;
intervertebral fusion
- From:
Journal of Xi'an Jiaotong University(Medical Sciences)
2016;(2):174-177,186
- CountryChina
- Language:Chinese
-
Abstract:
ABSTRACT:Objective To compare the clinical effects of Zero-P and traditional titanium plate with cage in treating single level cervical spondylosis.Methods We retrospectively analyzed the clinical data of 28 patients with single level cervical spondylosis who underwent anterior cervical discectomy and fusion (ACDF)by traditional titanium plate with cage (group A,n=16)or Zero-P implant (group B,n=16)in our department between January 2012 and January 2014.The intraoperative blood loss,operation time,postoperative JOA scores,JOA recovery rate,NDI scores,and dysphagia incidence in both groups were measured and compared.The changes of the midpoint interbody height (IBH),the cervical Cobb angle of the surgical segment and the cervical Cobb angle of C2 and C7 vertebral body were measured on the standing lateral cervical spine X-ray.Results The operation time was significantly longer in group A than in group B (P < 0 .0 1 ), but there were no significant differences in intraoperative blood loss between the two groups (P>0 .0 5 ).The incidence of dysphagia was lower in group B than in group A.The two groups did not significantly differ in JOA score or JOA improvement rate during the same period after operation (P>0.05).The NDI score in group B was significantly lower than that in group A (P<0 .0 5 )at 1 month and 6 months after operation,but showed no significant difference in preoperative and 1 2 months after operation (P>0 .0 5 ).The midpoint interbody height in group B was significantly greater than that in group A (P<0 .0 5 )1 2 months after operation,but showed no significant difference one month after operation.The cervical Cobb angle of the surgical segment was significantly greater in group B than in group A (P<0 .0 5 )after operation, but there was no significant difference in cervical Cobb angle of C2 and C7 vertebral body between the two groups at various time points (P>0.05).Conclusion Zero-p and traditional titanium plate with cage have similar effects in treating single level cervical spondylotic myelopathy,and Zero-P system has the advantages of lower incidence of dysphagia after operation,shorter operation time and better recovery of postoperative cervical physiological structure.