Evaluation the Value of Left Ventricular Rotation and Torsion in Pre-apical Hypertrophic Cardiomyopathy Diagnosis Using Two-dimensional Speckle Tracking Imaging
- VernacularTitle:二维斑点追踪显像评价左室旋转和扭转运动在早期心尖肥厚型心肌病诊断中的价值
- Author:
Guang SONG
;
Weidong REN
;
Jinling HU
;
Wei QIAO
;
Jing ZHANG
- Publication Type:Journal Article
- Keywords:
echocardiography;
speckle tracking imaging;
pre-apical hypertrophic cardiomyopathy;
twist
- From:
Journal of China Medical University
2015;44(8):704-708,713
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the diagnostic value of two-dimensional speckle tracking imaging in the evaluation of left ventricular rotation and torsion in pre-apical hypertrophic cardiomyopathy(PAHCM)patients. Methods A total of 26 patients with PAHCM,26 patients with hyperten-sive left ventricular hypertrophy(HLVH)and 26 healthy volunteers were recruited for the study. Two-dimensional echocardiographs were performed carefully. Two-dimensional images were obtained from the left ventricular apical four-chamber section,two-chamber section and two short-axis sec-tions,including mitral valve and apical levels. The peak subendocardial rotation(endo-rot),epicardial rotation(epi-rot),transmural torsion(mural-tor)and bulk rotation(bulk-rot)of each short-axis section were measured and analyzed using QLAB 9.1 software. Results In the mitral level, there was no statistically significant difference in endo-rot,epi-rot,mural-tor and bulk-rot between the PAHCM group and normal control group (P>0.05). There was statistically significant difference in endo-rot,epi-rot,mural-tor and bulk-rot between the PAHCM group and HLVH group (all P<0.05). There was statistically significant difference in endo-rot,epi-rot,mural-tor and bulk-rot between the HLVH group and normal control group(all P<0.05). In the apical level,there was no statistically significant difference in epi-rot among three groups(P>0.05). There was statisti-cally significant difference in endo-rot,mural-tor and bulk-rot between each two groups(P<0.05). There was statistically significant difference in G-tor between each two groups(P<0.05). The receiver operating characteristic curve analysis showed that the accuracy of differential diagnosis of G-tor PAHCM was high(the area under the receiver operating characteristic curve is 0.89),the sensitivity was 73.08%,and the specificity was 92.31%. Conclusion Two-dimensional speckle tracking imaging could accurately and quantitatively measure the left ventricular rotation and tor-sion in PAHCM patients. The G-tor could accurately screen and identify between PAHCM and HLVH.