Measurement of coronary tortuosity in three-dimension based on computed tomography coronary imaging
10.3969/j.issn.1671-8348.2015.22.025
- VernacularTitle:基于冠状动脉 CTA 图像对冠状动脉空间扭曲程度的量化测量
- Author:
Yixuan LIU
;
Chengming YANG
;
Chenfei WU
;
Jinhua CHEN
;
Weiguo ZHANG
;
Chunyu ZENG
;
Lingxi WANG
- Publication Type:Journal Article
- Keywords:
coronary vessels;
tomography,spiral computed;
coronary tortuosity;
coronary CTA;
tortuosity index
- From:
Chongqing Medicine
2015;(22):3093-3095,3098
- CountryChina
- Language:Chinese
-
Abstract:
Objective To quantitate coronary tortuosity and provide favorable conditions for understanding the hemodynamic effects caused by coronary tortuosity.Methods We obtained all images from 72 patients who received coronary computed tomo-graphy scanning.After image post-processing,we extracted the medial axis of three main coronary vessel and analysed its coordi-nates on three dimensions.Then we calculated the tortuosity coefficient of coronary artery.Results Tortuosity coefficient was 6.66±7.54 in anterior descending,13.43±12.85 in left circumflex,and 1 7.61 ±7.67 in right coronary artery.We had proved its validity by the changes in morphology with simulated shapes.Conclusion We proposed a new method for quantitating coronary tor-tuosity,by computed tomography coronary imaging.The measurement results would not be affected by projection plane,vessel length or other artificial factors.