Application of 3D-FlESTA Sequence in the Diagnosis of the Stenosis of Midbrain Aqueduct
10.3760/cma.j.issn.1008-6706.2010.01.016
- VernacularTitle:三维快速成像稳态采集序列在中脑导水管狭窄诊断中的应用
- Author:
Jianju FENG
;
Peiyou CHEN
;
Jian XU
- Publication Type:Journal Article
- Keywords:
Three-dimensional fast imaging employing steady-state acquisition;
Aqueduct of midbrain;
Stenosis;
Magnetic resonanee imaging
- From:
Chinese Journal of Primary Medicine and Pharmacy
2010;17(1):34-35,插8
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the evaluation of three-dimensional fast imaging employing steady-state acquisition(3D-FIESTA) sequence in the diagnosis of non-tumorous midbrain aqueduct stenosis.Methods 48 patients with non-tumorous midbrain aqueduct stenosis were performed by conventional SE sequence and 3D-FIESTA sequence on a 1.5T superconductive MR unit.Then the advantage on showing aqueduct of midbrain foramen was retrospectively analyzed.Results The detecting rate of midbrain aqueduct stenosis was 98% (47/48) on 3D-FIESTA sequence and 79% (38/48) on conventional SE sequence,3D-FIESTA was more advanced on showing the aqueduct of midbrain(P <0.01).Conclusion The combination of 3D-FIESTA with MPR can clearly show the midbrain aqueduct stenosis,and be a new MRI examination way of obstructive hydrocephalus.