Percutaneous Fixation of Distal Tibia Comminuted Fracture by Using Normal Anatomical Plate
- VernacularTitle:普通解剖钢板经皮微创内固定治疗胫骨远端粉碎性骨折
- Author:
Song SHAO
;
Ran CHEN
;
Weidong CHANG
- Publication Type:Journal Article
- Keywords:
Distal tibia fracture;
Minimally invasive percutaneous plate osteosynthesis;
Normal anatomical plate
- From:
Chinese Journal of Minimally Invasive Surgery
2005;0(07):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) for the treatment of distal tibia comminuted fracture by using normal anatomical plate. Methods Between January 2007 and July 2008,18 cases of distal tibia facture were treated by MIPPO using anatomical plate. The clinical data of the patients were reviewed. Results A mean of 6.5 cm incision (5.0-8.5 cm) was made in the patients; the intraoperative blood loss ranged from 60 to 300 ml (mean,145 ml);and the operation time ranged from 30 to 120 min with a mean of 63 min. After the surgery,2 patients developed mild skin necrosis,and was then cured by conventional therapy; no patient had nonunion of the fracture,failure of internal fixation,or delayed wound healing. The 18 cases were followed up for a mean of 8 months (range,4 to 10 months); all of them were healed clinically and could walk without crutch in 4 months postoperatively. According to Johner-Wruhs score system,11 were excellent and 7 were good; the excellent-good rate was 100%. Conclusions MIPPO with anatomical plate is an optimal treatment for distal tibia comminuted fracture with advantages in protecting the soft issues and bony blood supply,promoting the wound-healing process,and reducing the rate of complications.