Biomonitoring Ethylene Oxide Sterilization Process and Reason of Sterilization Failure
- VernacularTitle:手术室环氧乙烷灭菌生物监测方法的改进
- Author:
Xin DONG
;
Feng SONG
- Publication Type:Journal Article
- Keywords:
Ethylene oxide;
Biomonitoring;
Reason of sterilization failure
- From:
Chinese Journal of Nosocomiology
2005;0(11):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE Through biomonitoring the effect of ethylene oxide sterilization process,to discuss the precision usage and management of the technology in operating room,and instruct the sterile job in operating room in the future.METHODS The process of ethylene oxide sterilization was monitored by biological indicators to realize the whole controlling of sterilization effects.RESULTS In the whole 210 sterile articles,202 were qualified,and 8 were disqualified.CONCLUSIONS With correct procedures of sterilization and assurance the qualification of the biomonitoring indicators,the optimal quality of sterilization would be achieved.