Contrast Test of Injection Indisposition between Disome and Monomer Diagnostic Opaque in Femoral Arteriogram
- VernacularTitle:双体与单体造影剂在股动脉造影中注射性不适的对比试验
- Author:
Xuesong TANG
;
Yu ZHOU
- Publication Type:Journal Article
- Keywords:
iodixanol;
iohexol;
diagnostic opaque;
femoral arteriogram;
safety;
efficiency
- From:
Chinese Medical Equipment Journal
2003;0(10):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the safety and efficiency of non -ionic monomer diagnostic opaque, iodixanol (Visipaque) and that of non -ionic disomer diagnostic opaque, iohexol (Omnipaque). Methods By comparing retrospectively the DSA opacification of 60 patients from 2006 to 2007, patients′ indispositions, adverse reactions and pictorial efficiency were recorded respectively. Results In the control group, iodixanol showed less indisposition caused by injection than iohexol and there′ s no obvious difference of indisposition. Both images met diagnostic requirements. Conclusion Both iodixanol and iohexol are safe, efficient and well -tolerant diagnostic opaque. Iodixanol is better than iohexol in indisposition caused by injection.