Arthroscopic Internal Fixation by Using Anchor for Tibial Eminence Fracture
- VernacularTitle:关节镜下带线锚钉治疗胫骨髁间嵴撕脱骨折
- Author:
Guofeng LI
;
Yubin WANG
;
Junfeng CAI
- Publication Type:Journal Article
- Keywords:
Tibial eminence fracture;
Anchor fixation;
Arthroscopy
- From:
Chinese Journal of Minimally Invasive Surgery
2005;0(08):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To report the clinical outcomes of arthroscopic internal fixation by using anchor for tibial eminence fracture.Methods From January 2004 to January 2005,12 cases of tibial eminence were treated by arthroscopy with anchor fixation.Rehabilitation therapy was carried out after the operation.Results The mean operation time was 41 minutes(range 37 to 47).No patient had postoperative complications.They were followed up for 15 to 27 months(mean,23 months).The postoperative Lysholm score ranged from 91 to 98 with a mean of 93.The patients could extend the knee in a normal range,without pain or locking.Conclusion Arthroscopic internal fixation using anchor is a safe,simple,and effective treatment for patients with tibial eminence fracture.