Implantation of pedicle screw threatening the aorta following thoraco-lumbar burst fracture: One case report
- VernacularTitle:因胸腰椎爆裂骨折置入椎弓根螺钉危及主动脉1例报告
- Author:
Changsong ZHAO
;
Huasong MA
;
Xuefeng ZHOU
;
Kewen BAI
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2007;0(26):-
- CountryChina
- Language:Chinese
-
Abstract:
One patient with the pedicle screw threatening the aorta was treated with adjusting the position of pedicle screw by anterolateral approach. No nervous lesion was found after adjusting. Radiograph showed the position and length of screw at T11 left pedicle of vertebral arch were good. No adverse reaction was detected after 2-years of follow-up.