Arthroscopic reduction and fixation of avulsion fracture of the posterior cruciate ligament from the tibia through an additional posterolateral portal
- VernacularTitle:关节镜下经膝后外侧附加入口复位内固定治疗后交叉韧带胫骨止点撕脱性骨折
- Author:
Yong HU
;
Shiming ZHANG
;
Yi LIANG
- Publication Type:Journal Article
- Keywords:
Posterior cruciate ligament;
Avulsion fracture;
Arthroscopy;
Internal fixation
- From:
Chinese Journal of Minimally Invasive Surgery
2005;0(07):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate surgical techniques and results of arthroscopic reduction and fixation for the treatment of avulsion fracture of the posterior cruciate ligament from the tibia through an additional posterolateral portal. Methods An additional posterolateral portal was established by using the inside-out technique under arthroscopic view.After a protective sleeve was placed through the portal and the displaced fracture was reduced,the fragment was fixed by the guide wire drilled through the sleeve temporarily.If the fluoroscopic control showed an anatomic reduction of the fragment and good placement of the wire,the self-attacked cannulated screw and washer was placed intra-articularly over the guide wire through the sleeve for the directive internal fixation of the avulsion fracture.Aggressive rehabilitation programs were recommended postoperatively.Results Except 1 case with 11 mm displacement and rotation of the fragment treated by the arthrotomy after the failure of arthroscopic reduction,the arthroscopic operation was accomplished in all the remaining 10 cases.The operative time was 63~98 min(mean,87.3 min).No injuries of popliteal vessels or nerves occurred.The postoperative X-ray firms showed an anatomic reduction of the fragment and good placement of the screw and washer.With the negative posterior drawer test confirmed by the physical examination,normal range of motion of the injured knee joint and gait were achieved in the 10 patients at 4~7 weeks after surgery.The bone union was confirmed by X-ray films at the 3 months postoperatively.The computer KT-2000 arthrometer measurements of posterior tibial displacement of both knee joints showed side-to-side difference not more than 1.2 mm in 6 patients at 5 months after surgery.Conclusions The additional posterolateral portal can be established by the arthroscopic inside-out technique safely.The displaced fragment of the avulsion fracture of the posterior cruciate ligament from the tibia can be reduced and fixed with the self-attacked cannulated screw and washer arthroscopicly.