Abstract:
OBJECTIVE To study the bactericidal efficacy of glutaraldehyde,and its stability and change in pH value.METHODS The carrier quantity bactericidal test,field mimic bactericidal test,stability test,pH value detection,periodical biological surveillance and follow-up investigation of hospital infection were used.RESULTS After using of 20 000 mg/L of neutral glutaraldehyde on Candida albicans(ATCC 10231),Pseudomonas aeruginosa(ATCC27853),Escherichia coli(ATCC 25922) and other 3 clinical isolates separately for 3,5,and 10 min,the average killing rate was 97.90%,99.83% and 100.00%;on the field mimic bactericidal test with MRSA contaminated gastroscope,the average killing rate was 87.84%,99.50%,and 100.00%,respectively.The concentration of disinfectant after storaging 14d on 54℃ was decreased,only loss 1.46%,the concentration loss of disinfectant on using endoscope 5,7,and 14d after disinfection was 2.64%,0.69% and 0.94%,respectively.The value of pH was decreased from 7.22 to 6.00,6.50,and 6.20.The qualification rate of 260 various endoscopes after surveillance was 100.00%.Their was one of hospital infection happened among 3 200 patients after endoscopy which were followed up.CONCLUSIONS The results show that,only under the following circumstances,namely the concentration of glutaraldehyde being no less than 20 000mg/L and the action time being no less than 10 min,timely alteration of glutaraldehyde,and regular biological and concentration monitoring could the disinfection of endoscope be qualified so that hospital infection can be prevented,and medical dispute may be put to an end.