Simulation study based on models of cerebral hemorrhage in electrical impedance tomography
- VernacularTitle:电阻抗断层成像脑出血模型的仿真研究
- Author:
Ansheng NI
;
Guosheng YANG
;
Xiuzhen DONG
;
Feng FU
;
Xinya ZHU
- Publication Type:Journal Article
- Keywords:
electrical impedance tomography;
cerebral hemorrhage;
simulation
- From:
Chinese Medical Equipment Journal
2004;0(08):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To build finite-element models of cerebral hemorrhage on which a simulation study of electrical impedance tomography(EIT) is based.Method With a kind of four-layer concentric circle model of head,finite-element method and dynamic NOSER algorithm are performed to reconstruct the images.Result As to the single-focus model of the cerebral hemorrhage,the focus can be clearly imaged,while to the several-focus model,the focuses can be imaged with vaguely adjacent boundaries.Conclusion The dynamic NOSER algorithm is an effective method to image cerebral hemorrhage in EIT.