Evaluation for Disinfection Effect of Air Disinfectors
- VernacularTitle:空气消毒器现场消毒效果评估
- Author:
Yubin XING
;
Hua WEI
;
Jijiang SUO
;
Ning JIA
;
Yune YUAN
- Publication Type:Journal Article
- Keywords:
Air disinfector;
Disinfection
- From:
Chinese Journal of Nosocomiology
2006;0(07):-
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE To select applicable air disinfectors that can be used at indoor dynamic state to disinfect air in hospital.METHODS Some different air disinfectors were installed different volumetric rooms.To detect indoor air bacterial content before and after running the air disinfectors at quiet state and dynamic state.To evaluate the disinfection effect of these air disinfectors according to the eliminateion rates.RESULTS At quiet state,the indoor bacteria eliminateion rate exceed 90% after the air disinfectors running 0.5h.So the disinfection were qualified.At dynamic state,these air disinfectors showed good lasting disinfection effect.CONCLUSIONS The air disinfectors solve the problem of indoor air disinfection at dynamic state.It is imperative that select and use exactly the air(disinfectors) to get good disinfection effect.