Treatment of radial head fractures by replacement with floating cup radial head prosthesis
- VernacularTitle:桡骨小头假体置换治疗桡骨小头骨折
- Author:
Guohua MEI
;
Peizhu JIANG
;
Cunyi FAN
- Publication Type:Journal Article
- Keywords:
Radial head;
Fracture, comminuted;
Prosthetic replacement
- From:
Chinese Journal of Orthopaedic Trauma
2002;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To report the preliminary clinical results of treatment of severely comminuted radial head fractures by replacement with floating cup radial head prosthesis. Methods In the period from August 2002 to June 2005, replacement with floating cup radial head prosthesis was performed to treat 10 cases of Mason Ⅲ , Ⅳ radial head fractures, of whom 9 were acute fractures and 1 old. Results All the patients were followed up for 6 to 40 months (mean 14.9 months). The mean flexion/extension of the elbow was 133.5? /9.0? , while the mean pronation/supination of the forearm was 78.5? /84.0? . There were 3 cases of mild pain, 1 case of mild valgus instability in the elbow and 3 cases of mild weakness. The Broberg and Morrey elbow scores averaged 93. The result was excellent in 6 cases, good in 3 and fair in 1, the excellent and good rates were 90% . Conclusion The replacement with floating cup prosthesis shows satisfying preliminary clinical outcome in the treatment of radial head fractures unable to be reduced, while its long- term result needs further follow- up