Clinical application of gasless laparoscopy
- VernacularTitle:非气腹腹腔镜技术的临床应用
- Author:
Hongbing XU
;
Chunfang GAO
;
Mingfang QIN
- Publication Type:Journal Article
- Keywords:
Laparoscopy;
Modified;
Gasless laparoscopic device
- From:
Chinese Journal of Minimally Invasive Surgery
2001;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the operative design, safety evaluation and feasibility of gasless laparoscopic operations. Methods The gasless laparoscopic devices (GLD) were applied to 124 cases of laparoscopic choledocholithotomy with T-tube drainage, 56 cases of laparoscopic choledocholithotomy with primary bile duct suture, 1 case of laparoscopic choledochocystectomy hepaticojejunostomy, 15 cases of modified gasless laparoscopic choledochojejunostomy, 1 case of hand-assisted laparoscopic megalosplenic resection and portozygos disconnection, and 1 case of gasless device assisted laparoscopic splenectomy. Results All the operations were successfully conducted, without any severe complications. Follow-up for 1~9 years in 129 cases of biliary duct operations found 1 case of recurrence. Follow-up for 3~12 months in 2 cases of splenic operations found no recurrence. Conclusions Gasless laparoscopic operations in this study have reached minimally invasive outcomes, proven to be safe and feasible.