Usefulness and safety of transtfaoracic echocardiogra phyguiding transcatheter closure of atrial septal defect
- VernacularTitle:经胸超声心动图引导Amplatzer及Sideris两种封堵器介入治疗房间隔缺损疗效评价
- Author:
Ping LIU
;
Jianping ZENG
;
He HUANG
- Publication Type:Journal Article
- Keywords:
Echocardiography;
Atrial septal defect;
Heart cathetelization
- From:
Chinese Journal of Interventional Cardiology
1996;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the efficiency, safety and complications of transcatheter closure of atrial septal defect (ASD) using Amplatzer and sideris occluder under the guidance of transthoracic echocardiography and fluoroscopy. Methods Fourteen patients of ASD, 6 male and 8 female, age ranged from 2.6 to 43 years old, were treated by transcatheter closure of ASD with Sideris or Amplatzer occluders. All cases were guided by thansthoracic echocardiography and fluoroscopy. Results The diameter of ASD (balloon stretched diameter) was 14-34 mm (24.16 ? 5.16)mm. The Amplatzer devices were used in 9 cases, all of them were successfully occluded with satisfactory results. Of 5 patients treated by Sideris buttoned devices, 4 had success procedure and one failed, in which unbuttoning occurred and retrieval of the device was performed by emergency surgery. Conclusion Transcatheter closure of ASD is a simple and convenient method with a high success rate and reliable curative effect. The indication of Amplatzer method is much wider and the instant success rate after the procedure is much higher than those of Sideris device. Thansthoracic echocardiography plays a key role for guiding transcatheter closure of ASD in this study.