Clinical values of endoscopic argon plasma coagulation treatment of gastrointestinal polyps
- VernacularTitle:内镜下氩离子凝固术治疗消化道息肉的体会
- Author:
Yuan GAO
- Publication Type:Journal Article
- Keywords:
Endoscopy;
Argon plasma coagulation;
Polyp
- From:
Journal of Chongqing Medical University
2007;0(09):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the values of the endoscopic argon plasma coagulation (APC) in the treatment of gastrointestinal polyps. Methods:The gastrointestinal polyps confirmed by endoscopy and pathology were treated with argon plasma coagulation generated by ERBE APC 300 made in German ERBE Company. Results:A total of 78 polyps (59 flat and thin sessile polyps and 19 pedunculated polyps) in 23 patients were all cured with APC. 59 flat, thin and sessile polyps were only treated with APC, whereas 19 pedunculated polyps were treated with snared polypectomy and APC ablation of residual tissue. Time of coagulation for every polyp was determined by its size and location. Polyps became flat and thin after(1~7)times of coagulation. As many as 10 polyps could be treated at one time, but for patients with more than 10 polyps, several times of treatment were needed. Conclusion:Treatment of gastrointestinal polyps by APC is an effective and safety method with low side effects. It can be the first choice of methods for the treatment of flat and thin sessile gastrointestinal polyps or polypoid projection.