Survey on patient dose in cardiac intervention
- VernacularTitle:心脏介入患者受照剂量研究
- Author:
Mei BAI
;
Bin LIU
;
Junzheng ZHENG
- Publication Type:Journal Article
- Keywords:
Cardiac intervention;
Patient dose;
Peak skin dose;
Dose-area product
- From:
Journal of Interventional Radiology
1994;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To collect information of patient doses of interventional radiology in Beijing Xuanwu Hospital,and investigate correlation between the peak skin dose(PSD) and dose-area product(DAP).Methods Radiation doses from 135 patients have been studied including 84 coronary angiographies(CAG) and 51 percutaneous transluminal coronary angioplasties(PCI).Dose-area product(DAP) values,cumulative dose(CD) at interventional reference points,fluoroscopy times,total number of cine frames were collected for each patient.Skin dose measurements were made with thermoluminescent dosimeters(TLD) placed as a 10 ? 9 arrays of TLDs on the body.The grid of TLDs arrays was 5 ? 4 cm.Results Mean values for dose-area product were 2690.84 ?Gym2 for CAG and 7946.91 ?Gym2 for PCI.Mean values for CD were 431.6 mGy cm2 for CAG and 1395.3 mGy for PCI.Mean fluoroscopy times were 2.9 min for CAG and 10.9 min for PCI and mean number of frames were 544 and 945 for CAG and PCI,respectively.PSD values ranged from 26.18 to 120.37 mGy for CAG and 38.91 to 184.79 mGy for PCI.The relationship between DAP and PSD was r = 0.52 for CAG and r = 0.54 for PCI.The correlation of PSD with CD was r = 0.45 for CAG and r = 0.53 for PCI.Conclusion Comparison shows that patients DAP,CD and fluoroscopy time values were comparable with other publications.Skin dose values of investigated patients are below the threshold dose for radiation skin injury(2 Gy).There is no good relationship between DAP and PSD.So calculation of individual maximum skin dose based on DAP data is not reliable and needs to find a new reference value for skin dose.(J Intervent Radiol,2007,16:222-225)