Abstract:
Objective The Neuroform stent is the first self-expandable intracranial stent designed for the treatment of wide-necked intracranial aneurysms. We report the results of our preliminary experience in combination of this stent and detachable coils to treat patients with wide-necked intracranial aneurysms. Methods From August 2003 to August 2004, 22 patients with 24 wide-necked intracranial aneurysms were treated with combination of Neuroform stents and detachable coils. There are 19 acutely ruptured aneurysms and 5 unruptured aneurysms. Results Twenty-three aneurysms were successfully treated by combination of stents and detachable coils. In one patients with multiple aneurysms, an unruptured small wide-necked aneurysm was successfully treated with the stent deployment but failed coiling. All stents were deployed successfully. Mild stent displacement was found in one patient. Intraaneurysmal contrast media stagnation was not seen immediately after the stents deployment. Total (100%) obliteration of the aneurysm was achieved in 18 aneurysms, and subtotal (more than 90%) obliteration was achieved in 5 aneurysms. All the parent arteries were patency after treatment. In 2 aneurysms, some small coil loops were herniated into the parent artery from the stent struts but did not affect the blood flow within parent artery. No symptomatic brain ischemia was found in perioperative period. Seventeen patients were received a mean of 3 months follow-up and control angiography. No recurrence was found in 16 patients. Recanalization was found in one patient, he received a second embolization and the aneurysm was totally oberliterazation.Conclusions The Neuroform stent is a very safe and effective intracranial stent for treatment of wide-necked intracranial aneurysm. It is very suitable for wide-necked intracranial aneurysm with severely tortuous parent artery. Due to lack of significant radial strength of the stent, the stent can be shifted by a microguidewire or microcatheter when performed superselective catheterization. Because the big struts of this stent, the change of intraaneurysmal hemodynamics after stent deployment was notevident as coronary stent. So dense packing the aneurysm is advocated. Care must be taken when packing the detachable coils after the stent deployment. The administration of dual anti-platelet drug to prevent stent-related thromboembolic complications in the perioperative period is important. Although a good angiographic result is achieved, long-term angiographic follow-up is still necessary.