Bacterial Endotoxin Test of Pulse-Engendering Injection
- VernacularTitle:生脉注射液的细菌内毒素检查
- Author:
Ping LIU
;
Fangyin YANG
;
Hankun HU
- Publication Type:Journal Article
- Keywords:
Pulse-Engendering Injection;
bacterial endotoxin;
TAL
- From:
Chinese Traditional Patent Medicine
1992;0(05):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To perform the bacterial endotoxin test of Pulse-Engendering Injection.Methods: The interference actions of the different dilutabilities of injection at the greatest effective diluent range were observed with some sensitivity of TAL. Results: When 0.5EU/ml sensitivity of TAL was used and the dilutability of sample was 1∶8, the injection showed obvious enhancement action, but when 0.25EU/ml senitiity of TAL was used and the dilutability was 1∶16, the enhancement action of injection could be eliminated. Conclusion: The bacterial endoxin test can be carried out with 0.25EU/ml sensitivity of TAL when the dilutability of sample is 1∶16, the limit dose of bacterial endotoxin is controlled thereby.