Reproducibility of measurement of liver volume using multi-slice spiral CT
- VernacularTitle:多层螺旋CT肝脏体积测量的可重复性研究
- Author:
Jian SHU
;
Jiannong ZHAO
;
Dajing GUO
;
Yindeng LUO
- Publication Type:Journal Article
- Keywords:
CT;
liver volume;
reproducibility
- From:Journal of Third Military Medical University
2003;0(11):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the reproducibility and agreement in the measurement of liver volume with multi-slice spiral computed tomography(CT).Methods Spiral CT was performed in 20 cases(14 healthy volunteers and 6 patients with cirrhosis).Images were transferred to a workstation,and volumes were measured by three observers with 5-year abdominal CT experience.Each observer performed the measurements in all subjects twice.Intra-observer and inter-observer variability was calculated using analysis of variance of the repeatedly measured results.The agreement was analyzed with the intra-class correlation coefficient(ICC).Reliability analysis in inter-observer was performed with Cronbach's alpha coefficient.Results Data measured by Observer A were(1 265.53?421.43)cm3 and(1 272.30?414.73)cm3 [difference:(0.80?2.20)%,P=0.15,ICC=0.998 8],Observer B(1 299.97?403.48)cm3 and(1 310.23?404.04)cm3 [difference:(0.90?1.90)%,P=0.07,ICC=0.998 3],Observer C(1 282.18?425.91)cm3 and(1 289.73?424.66)cm3 [difference:(0.70?2.60)%,P=0.19,ICC=0.998 3],respectively.The mean liver volumes by the three observers were(1 268.91?418.07)cm3,(1 305.10?403.59)cm3,and(1 285.97?425.10)cm3,respectively(P=0.07,ICC=0.986 9,Cronbach's alpha coefficient=0.995 6).Conclusion High reproducibility and agreement in the measurement of liver volume can be achieved with multi-slice spiral CT.