The applying Diver CE thrombus-aspirating device in acute myocardial infarction
- VernacularTitle:Diver CE血栓抽吸装置在急诊冠状动脉介入治疗中的应用
- Author:
Lili ZHANG
;
Yanhua LI
;
Hong ZHENG
- Publication Type:Journal Article
- Keywords:
Acute myocardial infarction;
Percutaneous coronary intervention;
Distal embolization;
Thrombus-aspirating
- From:
Chinese Journal of Practical Internal Medicine
2006;0(22):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To assess the effect and safety of applying Diver CE thrombus-aspirating device during direct percutaneous coronary intervention(PCI)in pations with ST-segment elevation myocardial infarction(STEMI). Methods Select 46 patients with STEMI who underwent direct PCI between July,2006 and June,2007 in Fushun Central Hospital. Dividing these patients into thrombus-aspirating group and direct PCI group,comparing the difference in chest pain relieving.magnitude of ST-segment declining in 2h,TIMI flow grade 3,the maximum value of CK and CK-MB,EF and MACE outcome(death、myocardial infarction and targert vessel revascularization).Results The percent of chest pain relieving、magnitude of ST-segment declining 、TIMI flow grade 3、the maximum value of CK and CK-MB,and EF in thrombus-aspirating group are piror to the direct PCI group(P0.05).Conclusion applying Diver CE thrombus-aspirating device during PCI can obviously reduce thrombus in coronaty artery and distal embolization,improve myocardial reperfusion more effectively.