Comparison between 8-hour pH monitoring test in gastroesophageal reflux disease and 24-hour pH monitoring.
- VernacularTitle:含餐8h食管pH监测与常规24h pH监测对胃食管反流病的诊断价值比较
- Author:
Guijian FENG
;
Yulan LIU
;
Lili ZHAO
- Publication Type:Journal Article
- Keywords:
Gastroesophageal reflux disease;
Esophageal pH monitoring;
Diagnosis
- From:
Chinese Journal of Practical Internal Medicine
2006;0(18):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To determine the diagnostic value of 8-hour pH monitoring in gastroesophageal refulux disease(GERD)and compare its sentivity and specificity with that of 24-hour monitoring.Methods Patients had been given esophageal manometry and ambulatory 24-hour pH monitoring.The 8-hour datas were analyzed from the standard ambulatory 24-hour pH recording.GERD was confirmed if DeMeester Score was no less than 14.72 according to the routine pH monitoring,then DeMeester score was reanalyzed according to 8-hour period,the same dignosis cirteria was used for 8-hour pH monitoring.Results Totally 221 patients met the entrance criterion.The 8-hour test had a sensitivity of 93.5% when compared to the 24-hour test and a specificity of 95.9%.Kappa test and Mc-nemar test verified the two monitor periods were with considerable consistency.The Pearson coefficient correlation was 0.929 with P value less than 0.001.Conclusion The 8-hour analysis is as sensitive and specific as the routine test for demonstrating GERD.By using this method,patients may suffer less discomfort and appear enhanced compliance.