Evaluation of ECP Level Determination Under Different Temperature for Asthma.
- VernacularTitle:不同温度测定血ECP水平对支气管哮喘的结果评价
- Author:
Huaikai WEN
;
Songdao YE
;
Yiqun RUAN
- Publication Type:Journal Article
- Keywords:
Eosinophil Cationic Protein;
Asthma;
Temperature;
Anticoagulants
- From:
Journal of Medical Research
2006;0(03):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the influence of the treatments including temperature and anti-coagulation agent (EDTA-K_2) during the blood samples collection on the ECP level. Methods The serum and plasma samples were collected from 20 childs with asthma and 25 healthy childs under different temperature (25℃ and 37℃). ECP levels were determined by using immobile double-site enzyme amplified chemiluminescence immunoassay.Results The serum ECP level of the treatment under 37℃ was significantly high (P0.05). The serum ECP level was significantly higher(P