Study on MRI-guided localizing technique in neuroendoscopic third ventriculostomy
- VernacularTitle:第3脑室底造瘘术MRI简易锁孔定位技术研究
- Author:
Xu WANG
;
Youzhi LIN
;
Zhanqiang HAN
;
Yanbin XU
;
Enzhong LIU
- Publication Type:Journal Article
- Keywords:
Ventriculostomy;
Stereotaxic techniques;
Magnetic resonance imaging
- From:
Chinese Journal of Radiology
2001;0(02):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate an accurate and applicable localizing method of puncture point for neuroendoscopic third ventriculostomy in neurosurgery so as to ensure that the neuroendoscope is led to the anterior membrane of mammillary body on the base of third ventricle directly. Methods Based on the MR characteristics including multiple directions and angles and high soft tissue resolution, the coordinate of puncture point was measured and calculated for neuroendoscopic third ventriculostomy in MRI. Results~The position of puncture point for neuroendoscopic third ventriculostomy was (127.2?9.9)mm to nasal root, or (17.1?5.6)mm in front of coronal suture and (20.3?4.7)mm to sagittal suture. The angle between the puncturing line and the cerebral falx was (12.3?1.9)?, and the depth from scalp to anterior membrane of mammillary body was (89.3?10.4)mm. Conclusion MRI-guided localization for neuroendoscopic third ventriculostomy is an accurate, simple, safe, painless, and applicable method.