Effectiveness of the LigaSure vessel sealing system in transvaginal hysterectomy
- VernacularTitle:结扎速血管闭合系统在经阴道子宫切除术中的应用
- Author:
Luxia JIAO
- Publication Type:Journal Article
- Keywords:
LigaSure vessel sealing system;
hysterectomy vaginal
- From:
Medical Journal of Chinese People's Liberation Army
1981;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the usefulness of the LigaSure vessel sealing system for vascular control during transvaginal hysterectomy and compared it with suture group. Methods One hundred and sixty-one transvaginal hysterectomy were performed with LigaSure while 62 with traditional suture from Sept 2002 to Mar 2003. Meanwhile, the operating time, the estimated blood loss, the postoperative recovery and hospital stay were explored. Results All of the surgery were successfully performed with both LigaSure and traditional suture. Compared with suture group the LigaSure has many advantages in operating time, estimated blood loss and postoperative recovery. Conclusion For transvaginal hysterectomy LigaSure vessel sealing system is a more useful instrument and also an ideal option. It may be used safely in large, difficult uterus during transvaginal hysterectomy with less blood lose, short operating time, quick recovery after surgery.