Determination of CA 15-3 and CA 125 by ELISA technique
- Author:
Hoang Van Son
- Publication Type:Journal Article
- Keywords:
CA 15-3, CA125
- MeSH:
Enzyme-Linked Immunosorbent Assay;
methods;
serum
- From:Journal of Vietnamese Medicine
2003;287(8):18-21
- CountryViet Nam
- Language:Vietnamese
-
Abstract:
In Trang An polyclinics in Ha Noi, with ELISA technique, 35 healthy people (27 female aged 20-38, 8 male aged 25-37) undergone an examination of serum CA153-3 and 31 other healthy people (17 female aged 21-38, 14 male aged 22-41) an examination of resum CA125. The technique is complicated needing precaution and accuracy; for each examination, it is recommended a standard graphic with a standard sample determined antigen concentration. CA15-3 normal concentration is 2.37-18.17 U/ml, and CA125 is 7.17-38.37 U/ml