Preliminary study of 3D arterial spin labeling in diagnosis of ischemic cerebrovascular disease
10.3760/cma.j.issn.1673-4181.2013.06.007
- VernacularTitle:全脑容积灌注动脉自旋标记成像用于缺血性脑血管疾病的初步研究
- Author:
Hui MA
;
Fengtan LI
;
Yu ZHAO
;
Xinyu WANG
- Publication Type:Journal Article
- Keywords:
3D arterial spin labeling;
Dynamic susceptibility contrast;
Diffusion weighted imaging;
Transient ischemic attack;
Cerebral blood flow
- From:
International Journal of Biomedical Engineering
2013;36(6):344-347,后插2
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the feasibility and clinical application value of 3D arterial spin labeling (3DASL) technique in diagnosis of ischemic cerebrovascular disease.Methods Experiment 1:Controlgroup (n=30) and brain infarction group (n=20) were established.All patients were routinely examined including 3DASL and dynamic susceptibility contrast (DSC) enhanced series.The analysis of the control group was performed using signal intensity measurement in three paired regions of interest (ROI) which were selected in left hemisphere centrum semiovale and the opposite hemisphere mirror regions respectively.The ROIs of brain infarction group were selected in the lesion areas and their mirror region.The cerebral blood flow (CBF) of each ROI was measured with 3DASL and DSC respectively.The CBF ratio to each ROI and its mirror ROI were calculated.Data were compared using paired-t test.Experiment 2:Acute cerebral infarction (n=30) and transient ischemic attack (TIA) group (n=30) were established.All patients were routinely examined including 3DASL and diffusion weighted imaging (DWI).The positive rate and the area of the lesions were calculated respectively with 3DASL and DWI and compared.Results Experiment 1:Both the control and brain infarction group demonstrated agreement between 3DASL and DSC.The CBF ratios of the control group were 1.02±0.18 and 1.06±0.24 respectively and revealed no statistically significant between that of 3DASL and DSC (P>0.05).The CBF ratios of brain infarction group were 0.50±0.12 and 0.48±0.18 respectively,and also revealed no statistically significant between two methods (P>0.05).Experiment 2:The positive rate of acute cerebral infarction were 100% with both DWI and 3DASL.The areas of the lesion detected by both methods were:SDwI<S3DASL,n=22; SDWI ≈-S3DASL,n=8; SDWI>S3DASL,n=0.The positive rate of TIA by DWI was 0%,and 70% by 3DASL.Conclusion The noninvasive,safe and repeatable 3DASL technique is almost as sensitive as DSC in the measurement of CBF.However,and it is more sensitive than DWI in diagnosis of TIA.Combining 3DASL and DWI will be helpful in early diagnosis of TIA,finding ischemic penumbra and estimating the blood perfusion of ischemic cerebrovascular disease.