Doppler etrasound technique for assesment the parameters of right ventricle blood flow fulfilment in the patients of hypertension
- Author:
Ta Manh Cuong
- Publication Type:Journal Article
- Keywords:
Hypertension
- MeSH:
Hypertension;
Bload;
Diseases
- From:Journal of Vietnamese Medicine
2003;286(7):49-56
- CountryViet Nam
- Language:Vietnamese
-
Abstract:
Imaging of right ventricle and left ventricle blood flow fulfilment of 185 hypertention patients was studied in comparison with the imaging of 2 ventricle fulfilment of 77 healthy persons of same age hypertension patients whose left ventricle muscle mass is within normal limits, the maximum speed of fulfilment in diastolic first stage decreases dramatically. Conversely, maximum speed of systolic stage increases considerably. The E/A ratio of the fulfilment flow in lelf and right ventricles correlate significantly with the age, the systolic and diastolic blood pressure, the thickness of wall of ventricle and the ratio of ventricle wall, the left ventricle anterior and posterior diameter ratio