VDD Pacemaker in an Unipolar Lead for Clinical Practice
- VernacularTitle:单根电极导线心室起搏双腔感知双反应方式起搏器远期效果分析
- Author:
Zhiyong WANG
;
Wei LU
;
Yinghua BAI
- Publication Type:Journal Article
- Keywords:
Single-pass lead VDD Pacemaker Atrial-ventricular block Atrial triggered ventricular pacing
- From:
Chinese Journal of Practical Internal Medicine
2001;0(04):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To inquire into the forward clinical results of ventricular pacing, dual-chamber sensing, atrial-triggered, and ventricular-inhibited (VDD) Pacemaker in an unipolar lead.Methods 16 patients with the pacemaker were studied from 1993 to 2002, including 12 male patients and 4 female patients at 49 to 75 years old (average age 64 4 7 8 years old). They were in normal sinus rhythmia with complete or high degree atrial-ventricular block. Lead electrode was inserted through subclavian venous access, and the pacemaker was implanted in the same side as the electrode.Results All patients were followed up from 1 to 112 months (average 68 8 6 3 months) after pacemaker implantation. Their heart functions were improved, symptoms disappeared, life quality remarkably improved. Atrial sensing of VDD was good. One patient was died from coronary heart disease with heart failure by following up for 42 months, but the rest were healthy. Conclusions VDD pacemaker implantation was simple, easy to perform if its indication was appropriate. It could alleviate patients symptom and its therapy was effective. We should think highly of using VDD pacemaker, especially at poor region.