The application of sliding interleaved Ky(SLINKY) technique in MRA of head and neck
- VernacularTitle:滑动间隔Ky(SLINKY)采集技术在头颈部磁共振血管成像中的应用
- Author:
Hongyan NI
;
Jun LIU
;
Jianzhong YIN
;
Peng LI
;
Ji QI
- Publication Type:Journal Article
- Keywords:
Magnetic resonance angiography;
Head;
Neck;
Image processing,computer-assisted
- From:
Chinese Journal of Radiology
2001;0(01):-
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the application of SLINKY technique in MRA of head and neck by comparison of four TOF MRA methods. Methods We obtained images on 21 patients and 5 volunteers with SLINKY on all the 26 cases, MOTSA on 18 cases, single volume on 16 cases, and 2D on 12 cases. Three experienced radiologists evaluated the images, unknowing which method the images were. The evaluations included clearness of vessel branches, smoothness of vascular wall, and vascular continuity. Signal-to-noise (SNR), contrast-to-noise (C/Ns), and scan time were measured. Results SLINKY displayed vessel branches better and had better smoothness of vascular wall and vascular continuity than the other three methods(P